Request PDF | Current Reconstruction of Three-Phase Voltage Source Inverters Considering Current Ripple | Continuous and stable acquisition of accurate threephase
In , a desktop electric machine emulator implementation method was proposed based on phase voltage reconstruction. In , the real-time FPGA-DT was applied
Description This software module calculates three phase voltages impressing to the 3-ph electric motor (i.e., induction or synchronous motor) by using the conventional voltage-source inverter.
This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the
Different aspects of using the single-shunt reconstruction method for three-phase inverters were discussed in , where the authors studied the zero voltage sampling
Three-phase current reconstruction technique using dc current information in conventional two-level inverters can be used for the purpose of cost reduction and sensor fault tolerance.
An improved state-space average model of the ultra-high voltage inverter based on wavelet decomposition and reconstruction Fan Xie, School of Electric Power Engineering,
However, this three shunt scheme cannot accurately perform the current reconstruction in specific areas under a high voltage modulation range despite using three
Furthermore, a voltage reconstruction algorithm is applied to solve the inverter nonlinearities and the digital time-delay effect, so as to improve the accuracy of the identified
This work focuses on the motor control method based on single-sensor phase current reconstruction. Centering around the current detection issue in the three-phase bridge
Simulation and experimental results shows that the proposed method is able to perform desirable current and voltage reconstruction of inverters, and provide desirable power
Abstract—In this article, an enhanced short-horizon integration actual voltage reconstruction method based on nonlinear error inverse-compensation (NEIC-SHIVR) is proposed for voltage
This paper presents three phase current reconstruction methods for a three-level neutral point clamped inverter (NPCI) by measuring the voltage of a shunt resistor placed in the neutral
Different aspects of using the single-shunt reconstruction method for three-phase inverters were discussed in [7, 8, 9], where the authors studied the zero voltage sampling method and three
A real-time short horizon integration voltage reconstruction method based on field programmable gate array (FPGA-based) is proposed for the three-level neutral point clamped (NPC) inverter,
Index Terms—Fault-tolerant control, high frequency voltage injection, interior permanent magnet synchronous motor (IPMSM), phase current reconstruction, sensorless control, three-phase
This paper describes boundary conditions for phase current reconstruction of a three current-shunt inverter and suggests a voltage injection method to expand the
The accurate voltage reconstruction of voltage source inverter is an important issue for flux and speed estimations of AC drives.The reconstruction process of the output voltage was analyzed
An Improved Voltage Reconstruction Method for Current Source Inverter IEEE Transactions on Power Electronics ( IF 6.5 ) Pub Date : 2025-07-09, DOI: 10.1109/tpel.2025.3587254 Yupeng
This paper proposes methods to detect DC-link voltage in order to reconstruct three-phase voltage in current source inverter (CSI). Three-phase voltages in CSI are obtained by
Meanwhile, the current reconstruction method of a three-phase inverter via the use of a single sensor has been proposed . This method can reconstruct a three-phase current by detecting the branch current and phase current of the
This paper presents a voltage injection method for reconstructing phase currents from current signals measured on single current-shunt circuits with cost-effective and high-performance
The fault-tolerant control of two-level three-phase voltage source inverters has been extensively studied1–3, including two reconstruction aspects: hardware topology and software control
This paper proposes a current sensing method to eliminate the immeasurable areas in three-phase inverters using the shunt resistors. Conventional shunt resistor-based
Ultra-high voltage inverters are widely used as grid-connected devices in new energy grids, and the state-space average model is the most practical modeling method for
Request PDF | A new flux observer based on voltage reconstruction for three-level DTC inverter | A DTC-SVM sensorless induction motor control system based NPC three-level
FPGA-Based Short Horizon Integration Voltage Reconstruction Method for Three-Level Neutral Point Clamped Inverter. IEEE Trans. Ind. Electron. 68 (11): 10412-10421 (2021)
In this paper, a real-time FPGA-based short-horizon integration voltage reconstruction method is proposed for the three-level neutral point clamped (NPC) inverter. It
To improve the reliability of Two-level three phase voltage source inverters, a uniform fault tolerant strategy based on space vector pulse width modulation is proposed for
This paper presents a simple current sensing and reconstruction scheme for a VSI (Voltage Source Inverter) with three shunt resistors. Using the shunt resistors, the actual
6. CONCLUSION In this paper, a simple online adaptive compensation method of dead-time effects and inverter nonlinearity is presented. The output of the adaptive method is
FPGA-Based Short Horizon Integration Voltage Reconstruction Method for Three-Level Neutral Point Clamped Inverter. IEEE Trans. Ind. Electron. 68 (11): 10412-10421 (2021)
This paper proposes a current sensing method to eliminate the immeasurable areas in three-phase inverters using the shunt resistors. Conventional shunt resistor-based current sensing methods have
PDF | On Jan 1, 2022, Naizhe Diao and others published An Enhanced Short-Horizon Integration Actual Voltage Reconstruction Method Based on Inverter Nonlinear Error
Figure 2 depicts the reconstructed topology after a fault in the A-phase bridge arm occurs. Due to the topology reconstruction, the appropriate control algorithm of the inverter also needs to be modified. Two-level three-phase voltage source
This paper deals with the three-phase current reconstruction method under the low modulation index operation of three-phase three-level PWM inverters by using the single-shunt current signal
Due to the overloading, vibration, and harsh conditions, switching transistors in open-end winding five-phase permanent magnet synchronous motors (OWFP-PMSMs) drives are more
A different current reconstruction method was studied for two-level three-phase inverters in . The authors suggested the current reconstruction strategy based on online offset compensation. This method is applied for two-level three-phase inverters, and it is also appropriate for operations with a low modulation index.
Different aspects of using the single-shunt reconstruction method for three-phase inverters were discussed in [7, 8, 9], where the authors studied the zero voltage sampling method and three-phase current reconstruction using three shunts placed in the collectors of bottom inverter transistors, respectively.
Scientific Reports 14, Article number: 8819 (2024) Cite this article To improve the reliability of Two-level three phase voltage source inverters, a uniform fault tolerant strategy based on space vector pulse width modulation is proposed for different leg faults.
The three-level inverter operation with a modulation index less than 0.2 is achievable, and single-shunt current reconstruction is possible to perform. The proposed method can be used as part of a hybrid solution, together with the SVM shift method. As a disadvantage, due to the asymmetric SVM pattern, the current ripple increased.
Two-level three-phase voltage source inverters often apply two control methods: sinusoidal pulse width modulation (SPWM) and space vector pulse width modulation (SVPWM). The SVPWM owns a higher utilization rate of DC voltage and does not require triangular carriers, allowing it to be broadly employed 4, 5, 6.
The reconstructed topologies of inverters with different bridge arm faults are different, which makes the basic voltage vector phase of each reconstructed topology inconsistent, resulting in different calculations.